Comfort series heat pump s are designed simply to be reliable, efficient and affordable. As a heat pump they give you the benefit of summer cooling along with cooler season heating. Be sure to pair this outdoor model with the right, SEER-boosting indoor furnace or air handler to gain the most efficiency. LSV should be installed within 2 ft. (0.61 m) of outdoor unit with flow arrow pointing toward outdoor unit. Make the necessary electrical connections as shown on Fig. 20 and by following the Installation Instructions included with accessory kit. IMPORTANT: Flow arrow must point toward outdoor unit. UNIT BASE PAN Dimension in. Infinity ® 18VS Heat Pump 25VNA8. Even though only your outdoor cooling unit has called it quits. The Infinity 18VS could change that for you. Your Carrier. Carrier® Comfort™ - 3.5 Ton 15 SEER Residential Heat Pump Condensing Unit; Carrier® Comfort™ - 3.5 Ton 15 SEER Residential Heat Pump Condensing Unit. Carrier® heat pumps with Puron® refrigerant provide a collection of features unmatched by any other family of equipment. The 25HBC has been designed utilizing Carrier’s Puron.
Advertising
38YRA
Heat Pump—Outdoor Section
Installation and Start-Up Instructions
NOTE:
Read the entire instruction manual before starting the
![]()
installation.
This symbol https://everbeautiful668.weebly.com/blog/hp-color-laserjet-pro-mfp-m277dw-user-manual-pdf.
→
indicates a change since last issue.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions pack- aged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses and work gloves. Use
quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and the National Electrical Code (NEC) for special instal- lation requirements.
Recognize safety information. This is the safety-alert symbol
.
When you see this symbol on the unit or in instructions and
manuals, be alert to the potential for personal injury.
Understand the signal word DANGER, WARNING, or CAU-
TION. These words are used with the safety-alert symbol. DAN- GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.
Samsung fully automatic front load washing machine user manual. Before installing or servicing system, always turn off main
power to system. There may be more than 1 disconnect switch. Turn off accessory heater power if applicable. Elec- trical shock can cause personal injury or death.
INSTALLATION
Step 1—Check Equipment and Jobsite
UNPACK UNIT — Move to final location. Remove carton taking
care not to damage unit.
INSPECT EQUIPMENT — File claim with shipping company,
prior to installation, if shipment is damaged or incomplete. Locate unit rating plate on unit corner panel. (See Fig. 2.) It contains information needed to properly install unit. Check rating plate to be sure unit matches job specifications.
Step 2—Install on a Solid, Level Mounting Pad
If conditions or local codes require the unit be attached to pad,
tie-down bolts should be used and fastened through knockouts provided in unit base pan. Refer to unit mounting pattern in Fig. 2 to determine base pan size and knockout hole location.
When installing, allow sufficient space for airflow clearance,
wiring, refrigerant piping, and service. Allow 30-in. clearance to service end of unit and 48 in. above unit. For proper airflow, a 6-in.
clearance on 1 side of unit and 12 in. on all remaining sides must
be maintained. Maintain a distance of 24 in. between units. Position so snow, ice, and water from roof or eaves cannot fall directly on unit.
On rooftop applications, locate unit at least 6 in. above roof
surface. Place unit above a load-bearing wall and isolate unit and tubing set from structure.
Arrange supporting members to adequately support unit and
minimize transmission of vibration to building. Cms 2.0 user manual cameras for sale. Consult local codes governing rooftop applications.
Step 3—Elevate Unit
For proper drainage the heat pump must be raised off the mounting
surface. Fig. 4 shows unit with accessory support feet installed. Use accessory heat pump snow rack in areas where prolonged subfreezing temperatures or heavy snow occur. Refer to separate Installation Instructions packaged with the accessories.
For proper unit operation and reliability, this unit must be
installed with the field-supplied balance port, hard shut-off TXV. Do not install with evaporator coils having capillary tube metering devices.
Step 4—Remove Indoor AccuRater® Piston and Install
TXV
After removing existing AccuRater from indoor coil, install
field-supplied bi-flow hard shut-off TXV kit. (See Fig. 5 and 6.) For TXV kit part number and charging instruction, refer to TXV label in your unit. If the indoor unit (fan coil) comes factory- equipped with a bi-flow hard shut-off TXV, no TXV change is required.
Fig. 1—Model 38YRA
A92446
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1
4
Tab
5a 5a
PC 101
Catalog No. 533-890
Printed in U.S.A.
Form 38YRA-2SI
Carrier Heat Pump 50yq024300 User Manual 2016
8-95
Replaces: 38YRA-1SI
Advertising
![]() Carrier Heat Pump 50yq024300 User Manual Instructions